mirror of
https://github.com/refraction-networking/uquic.git
synced 2025-04-03 20:27:35 +03:00
fix flaky flow controller test
This commit is contained in:
parent
a6eca911de
commit
20816bb866
3 changed files with 7 additions and 7 deletions
|
@ -141,7 +141,7 @@ var _ = Describe("Base Flow controller", func() {
|
|||
|
||||
It("increases the window size if read so fast that the window would be consumed in less than 4 RTTs", func() {
|
||||
bytesRead := controller.bytesRead
|
||||
rtt := 20 * time.Millisecond
|
||||
rtt := 200 * time.Millisecond
|
||||
setRtt(rtt)
|
||||
// consume more than 2/3 of the window...
|
||||
dataRead := receiveWindowSize*2/3 + 1
|
||||
|
@ -162,7 +162,7 @@ var _ = Describe("Base Flow controller", func() {
|
|||
// this test only makes sense if a window update is triggered before half of the window has been consumed
|
||||
Expect(protocol.WindowUpdateThreshold).To(BeNumerically(">", 1/3))
|
||||
bytesRead := controller.bytesRead
|
||||
rtt := 20 * time.Millisecond
|
||||
rtt := 200 * time.Millisecond
|
||||
setRtt(rtt)
|
||||
// consume more than 2/3 of the window...
|
||||
dataRead := receiveWindowSize*1/3 + 1
|
||||
|
@ -181,7 +181,7 @@ var _ = Describe("Base Flow controller", func() {
|
|||
|
||||
It("doesn't increase the window size if read too slowly", func() {
|
||||
bytesRead := controller.bytesRead
|
||||
rtt := 20 * time.Millisecond
|
||||
rtt := 200 * time.Millisecond
|
||||
setRtt(rtt)
|
||||
// consume less than 2/3 of the window...
|
||||
dataRead := receiveWindowSize*2/3 - 1
|
||||
|
@ -204,7 +204,7 @@ var _ = Describe("Base Flow controller", func() {
|
|||
controller.epochStartOffset = controller.bytesRead
|
||||
controller.AddBytesRead(controller.receiveWindowSize/2 + 1)
|
||||
}
|
||||
setRtt(20 * time.Millisecond)
|
||||
setRtt(200 * time.Millisecond)
|
||||
resetEpoch()
|
||||
controller.maybeAdjustWindowSize()
|
||||
Expect(controller.receiveWindowSize).To(Equal(2 * oldWindowSize)) // 2000
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue